ProblemPossible causeRemedy
Mains plug disconnected.Plug in at mains socket.
Door cannot be opened with Set programme. Door can be opened at
the DOOR [T�R] button.Programme knob in OFF (AUS) posi-
any time by exerting pressure on the
tion.
door.
Fine filter not in place and/or large Install fine filter and/or snap large mesh
Door cannot be closed.
mesh filter not inserted correctly.filter into place.
The selected function cannot be
Display shows: SELECTION
combined with other programme Select another function.
ERROR.
settings.
Programme knob in OFF (AUS) posi-Turn programme knob to LIGHT (BE-
Drum light is not working.tion.LEUCHTUNG) or to any programme.
Defective light bulb.Replace light bulb (see next section).
Programme stops midway, Empty condensed water container, then
display shows: THE TANK IS Condensed water container is full.start programme with the START/
FULL, PLEASE EMPTY.PAUSE button.
Drying cycle ends shortly after Select Timed Drying or higher degree of
Not enough washing loaded or
programme starts. Display dryness (e. g., INTENSIVE DRY
washing loaded is too dry for select-
shows: PLEASE CHECK THE [STARKTROCKEN] instead of STOR-
ed programme.
LOAD.AGE DRY [SCHRANKTROCKEN]).
Possibly too much washing was
Washing is heavily creased.Observe recommended loads.
loaded.
Changing bulb for inside
light
Only use a special bulb which is designed specially
for dryers. The special bulb is available from the af-
ter-sales service, ET-Nr. 112 552 000-5.
1Warning! Do not use standard bulbs! These
develop too much heat and may damage the
machine!
1Warning! Before replacing the bulb, discon-
nect the mains plug; with a permanent con-
nection: fully unscrew or deactivate the fuse.
1.Unscrew covering bonnet from above bulb (this
can be found directly behind the loading aperture,
at the top; refer to ?Description of machine? sec-
tion.)
2.Replace defective bulb.
3.Screw covering bonnet back down.
1Warning! For reasons associated with safety,
the covering bonnet must be screwed down
tightly. If this is not done, the dryer must not
be operated.
25 |