WARNINGan earth connection.
The following warning is valid in the United
-----------------------------------------------------------
Kingdom only: as the colours of the wires in the
Please ensure that the following installationmains lead of this appliance may not
heights between the lowest part of the hoodcorrespond with the coloured markings
and the hob are adhered to:identifying the terminals in your plug, proceed
65cm above gas hobsas follows:
55cm above electric hobs- the wire which is coloured green and yellow
If the instructions for the installation of themust be connected to the terminal in the plug
hob specify a greater distance, then thiswhich is marked with the letter E or by the earth
should be taken into account.
symbol [ ], or coloured green or green and
The exhaust air must not be fed into any ductyellow;
used for electricity (central heating systems,
- the wire which is coloured blue must be
thermosiphons, water-heaters, etc.).connected to the terminal which is marked
Comply with the official instructions provided
with the letter N or coloured black;
by the appropriate authorities in merit when- the wire which is coloured brown must be
installing the cooker hood. In addition, exhaust
connected to the terminal which is marked
air should not be discharged into a wall cavity,with the letter L or coloured red.
unless the cavity is designed for that purpose.
When making the electrical connections,
The room must be well ventilated in case acheck that the voltage values correspond to
hood and some other heat equipment fed withthose indicated on the data plate inside the
an energy other than electricity (gas, oil, coalappliance itself. In case your appliance is not
heaters, etc) operate at the same time. In factfitted with a flexible cable and has no plug, or
the hood, disposing of air, could create a
has not got any other device ensuring double
vacuum in the room. The vacuum should notpole isolation from the electricity supply, with
exceed 0,04mbar. This prevents the gas
a contact opening distance of at least 3 mm,
exhausted by the heat source from beingsuch separating device ensuring
intaken again. It is therefore advisable to ensure
disconnection from the main must be included
the room contains air taps able to ensure ain the fixed installation. If your unit features a
steady flow of fresh air.
power lead and plug, position this so the plug
Check the rating plate inside theis accessible at all times.
appliance; if the symbol (doubleAlways switch off the electricity supply before
insulated) is printed, read the following:carrying out any cleaning or servicing
this appliance has such technicaloperations on the appliance.
particulars that it belongs to class II
insulation, therefore it must not be
USE
earthed.
The following warning is valid in the United-----------------------------------------------------------
Kingdom only: in case your cable is not fittedNever do flambé cooking beneath the hood.
with with a plug, read the following instructions;When frying, take particular care to prevent oil
as the colours of the wires in the mains leadand grease from catching fire. Previously used
of this appliance may not correspond with theoil is especially dangerous in this respect. Do
coloured markings identifying the terminals innot use uncovered electric hotplates.
your plug, proceed as follows:To avoid possible risks of fire always comply
- the wire which is coloured blue must bewith the indicated instructions when cleaning
connected to the terminal which is markedanti-grease grille and when removing grease
with the letter N or coloured black;deposits from the appliance.
- the wire which is coloured brown must be
connected to the terminal which is markedMAINTENANCE
with the letter L or coloured red.
-----------------------------------------------------------
Check the rating plate inside the
appliance; if the symbol (doubleRegular and thorough cleaning ensures
correct and long-lasting operation.
insulated) is NOT printed read the
following: ATTENTION: This applianceParticular care must be paid to the grease
grille which must be periodically cleaned in
must be earthed. When making the electrical
connections, check that the mains socket hasrelation to use (at least once every two months). |