Special accessories
Active carbon filterFlex tube kit
When the hood is used in recirculation mode anWhen the hood is to be connected to an evacuation
active carbon filter should be used.channel use the flex tube kit containing one evacu-
Order by the retaileration flex tube, one roof connecting duct and two
PNC 955 101 117tube clamps.
Order by the retailer.
PNC 391 414 201
Installation
Unpacking
Check that the cooker hood has no damages. Trans-
portation damages should immediately be reported
to the one responsible for the transport Damages,
Min
faults and eventually missing details should immedi-75 cmMin
65 cm
ately be reported to the seller.
Take care of the packing material so that small
children cannot play with it.
Placement
The hood is to be mounted on the wall or under a
wall cupboard.Fig. 4
When installed, the hood must be not less than 65
cm. above electric burners or 75 cm. above gas or
mixed-fuel burners. (Fig. 4).
I
Electrical connectionL
The hood has a power cord with moulded plug withI
earth connection to be connected to a wall outlet of
230 V.
The power cord length is 1,2 m.
II
Mounting of hood on wallLL
l Fix the drilling template to the wall (Fig. 5).
l Make 3 ? 8 mm holes in the wall. 2 at points I, 1Fig. 5
as desired at points L.
l Insert the three ? 8 mm expansion plugs into the
wall.
l Insert 2 5x45 screws at points I but do not tighten
them completely.
l Open the grid.
l Fit the hood into holes I, tighten the 2 screws.
l From inside the hood, insert the third 5x45 screw
into hole L (Fig. 6).Fig. 6
21 |