GROUND TERMINAL When the desired ice slab thickness is reached, the
harvest cycle begins and the following happens:
-/ -,,g
l Evaporator thermostat is satisfied
l Compressor keeps running
REAR VIEW OF UNIT r? l Condenser fan stops
COMPARTMENT l Water pump stops
(FROM BACK OF ~ l Hot gas solenoid opens
ICE MAKER) 0 Water inlet valve opens
l Excess water is flushed out of the drain pan
FIGURE 2
l Cutter grid is warm to the touch
_=
L//cceL ?
INSTALL STRAIN RELIEF Machine resumes freezing after slab is released from
LINE TERMINALS
evaporator and the cutting process begins.
CHECK OPERATION
When the storage bin is filled, bin thermostat opens.
Start the unit by turning the service switch to ?ON? l Cutter grid remains on
and opening the line water valve.
NOTE: Left is ?OFF? - Middle is ?ON? - Right is
?CLEAN.? In ?CLEAN? position, only the pump
operates. THINGS TO REMEMBER
The unit will make up to 25 kg. (55 Ibs.)of Ice per day
Check condenser fan to make sure It is revolving
under ideal conditions. These conditions are: (1) Room
temperature 21°C (70°F); (2) Water temperature 1 OoC
Water will not enter pump pan until freezing plate
gets cold and machine goes Into a harvest cycle. (5OOF).
As the room and water temperatures vary, so will the
Check for even water flow over freezing plate. Unrt
amount of ice produced. Higher operating tempera-
must be level for proper operation.
tures will result in reduced Ice production.
Check for desired ice cube thickness and, after 24
The storage bin has a maximum capacity of 16 kg. (35
hours, adjust If necessary. Maximum ice yield will be
obtained with Ice thickness 13 mm to 16 mm Ibs.). When the bin is filled, the unit stops making Ice.
The storage bin IS not refrigerated and some meltage
Replace grill.
will occur. This. too, varies with room temperature.
FREEZING CYCLE The unit needs good air crrculation to perform effi-
ciently Keep the front grill and the condenser clean.
L-N
The water system, including filter screen in the water
r----TL inlet solenoid valve. need to be cleaned penodically for
good circulation. Instructions are located on the inner
door panel.
OPERATING
INSTRUCTIONS
Before starting, wash out interror of cabinet with a Bak-
ing Soda solution of 30Gm.(l oz.) soda to 1 Liter (1 qt.)
of warm water. Rinse thoroughly.
Make certain the water is turned on
HOW IT WORKS
Turn switch to the ?ON? position.
0 Compressor runs
l Condenser fan runs IMPORTANT: Allow unit to run for 3 hours before
l Water pump runs (circulates water) expecting ice, and for 24 hours before trying to set
l Cutter grid is warm to touch the thickness control. |